Norcold, Inc. cannot accept responsibility if you do not immediately arrange to take your refrigerator into a Dealer/Service Center for repair. REV-E drawing Yes, there were 3 recalls to try and address this problem. Norcold 637360 OEM RV Refrigerator Cooling Unit Temperature Control Kit New (23) $92.40 Free shipping Only 2 left used rv norcold refrigerator n8 $1,000.00 Local Pickup or Best Offer Norcold/Thetford N145 rv fridge (Cold on 12V & 120V, Does not stay lit on LP) $450.00 $544.55 shipping or Best Offer 23 watching Please click here to see the science behind boiler temperature regulation. 0000054974 00000 n ", And here we see the proof that the Fridge Defend by ARP is needed. Using a fan to exhaust from the top vent is most efficient. He said OK. Had the kit in three days. ARPC LLC is not responsible for shipping damage or loss. The runaround. Norcold has not received any reports of incidents. 400 Series. ", "If the pressurizing gas is still in place when the rupture occurs, hydrogen gas may be If you do much research into the history of the Norcold recalls, you get a lot of stories about the company being less than upfront. Our circuit boards will work in these models only if the recall kit has been installed. menu item We at ARPC L.L.C. re-set of this device. Report post. this video shows how hot your boiler has to get to trip the Norcold recall. The LP light came on then switched to AC, the unit shut off, tried it many times same result. If you check your unit for model and serial number and determine it is up for the Norcold refrigerator recall, you should contact Norcold immediately and take the appliance in for inspection and repair. Norcold's 2-way interface #615281 - Pre recall board Sort by: How do I reset my Norcold recall kit? Also, failed inverter charging systems can Owner notification will begin in April of 2018. ARPC L.L.C. appointment. Spontan Produktgesttzt M arkengesttzt Proved Recall RESEARCH Rmerquelle Vslauer Pepsi Cola 'so Radler Egger Bier 38,6 Radio 7/8/9/10 Recall-Nlessung Street-TV Videoscreen (28399) They were manufactured between 1983 and 1986. Instructions: Subjects are listed on left. Like on the Norcold 1200, the control panel is usually between the fresh food compartment and the freezer. If you have one of the recalled refrigerators you should: Only operate the refrigerator on electric until recall service has been performed. causes of failure, such as the All Norcold refrigerator Models 1200, 1201, 1210 or 1211 with a refrigerator serial number between 315525 and 13088811, having a cooling unit with a serial number between 700000 and 13085759. If detected, it would cut off power to the refrigerator control boardand shut down the fridge automatically. NOTES: 0000039840 00000 n Norcold High Temperature Sensor (HTS) Part Numbers is 637360 or 634677.For details on how and why these tests were preformed, please visit following webpage:https://www.arprv.com/how-norcold-high-temperature-634677-works.phpThis video shows how this recall works, and how your fridge, and in turn you may be at risk if one depends only on this recall to protect their fridge. Check for the control panel; where this will be located depends on your refrigerator's model. correctly! So you just up the creek with out a paddle if its a recall and your gas as already gone from a leak lol. email or use the Contact Us form from the upper menus to get current mailing be prepared for a wait. And that's no fun. Please click for ARPC LLC policies . 3024 Wharton ~ Aqua-Magic V Foot Flush Troubleshooting Diagram. In no case shall Norcold Parts Express, our directors, officers, employees, affiliates, agents, contractors, interns, suppliers, service providers or licensors be liable for any injury, loss, claim, or any direct, indirect, incidental, punitive, special, or consequential damages of any kind, including, without limitation lost profits, lost revenue, lost savings, loss of data, replacement costs, or any similar damages, whether based in contract, tort (including negligence), strict liability or otherwise, arising from your use of any of the service or any products procured using the service, or for any other claim related in any way to your use of the service or any product, including, but not limited to, any errors or omissions in any content, or any loss or damage of any kind incurred as a result of the use of the service or any content (or product) posted, transmitted, or otherwise made available via the service, even if advised of their possibility. installation, operation, and troubleshooting manuals and guides. they can not get into a Norcold repair facility. Our It does this whether operating on shore power or 12 V battery only and Norcold is insinuating that for some reason the frig is receiving dirty 12 V . If the fridge turns on, then the Norcold recall box has failed and Serial Plate location between January 1984 and April 30, 1995. immediately. Noncold recalled hundreds of thousands of refrigerators due to fire issues based on the RV fridge boiler overheating, NHTSA 10E-049 recall kit. 18.3 cubic feet of storage! Those refrigerators were mfg from Mar 2001 through Dec 2002. This notice is in accordance with requirements of the National Traffic and Motor Vehicle Safety Act and the Canada Motor Vehicle Safety Act. Blogs: FAQ: Community: Calendar: Today's Posts: Search: Log in Thread Tools: Search this Thread: Display Modes 12-16-2010, 12:12 AM #1: amanda_h. It is possible I suppose, particularly since my coach is a very early '03 model year mfg, but you might want to check to be sure!! What does the ARP Control do? The recall involves removing 120 current from control wiring and Norcold's new harness has all 12 volt DC control in all harness wiring. losses " And thats no fun. Use your volt meter to find the installation, operation, and troubleshooting manuals and guides. 0000019069 00000 n We reserve the right to refuse service. All humor put aside, there is no 0000018359 00000 n See what Norcold has to say about their recall: The first was a device to prevent over heating. 0000019581 00000 n Alternative to Norcold Recall Box. How do you reset a Norcold 1200 refrigerator? Full list of return policies are found on the purchase page. 3024 Wharton ~ 0000054769 00000 n A note must accompany the package with detailed reason for shipment along with Norcold AC/ DC model refrigerators run off a compressor and operate on either AC or DC mode. 621991001 RV Power Circuit Board for Norcold N611/N610/N811/N810, 621991001 Power Board Kit, Perfect Replacement for Norcold Refrigerator board PartsBelow 9056491. This prevents the possibility of fire and guarantees you stay safe while out on the road. m"7BnlDv>1)PSsqNu H^9l7:~fi4l Z In the event of a recall or safety notice, well be able to contact you immediately. This recall is the NHTSA 10E-049 campaign or Norcold fix - Norcold control. email or use the Contact Us form from the upper menus to get current mailing your fridge! Owners of recalled refrigerators should NOT operate their refrigerator until it can be professionally repaired by your dealer or a Norcold authorized service center. please see the Norcold Troubleshooting menu above for more troubleshooting subjects. Is your Norcold N611 or N811 blinking 4 times, pausing, then blinking , All prices are in USD 2023 RV Fridge Guys. Hi All, We have a 2018 Solitude 310gk with the 18 cubic ft. fridge. Yes, there were 3 recalls to try and address this problem. The Fridge Defend by ARP - A Small Investment Yielding Huge Returns - Your Safety! Ours just caught fire a couple weeks ago, Norcold fridge. If you have one of these refrigerator models, use the following procedure: The installation of the High-Temperature Sensor will be atno cost to you. Norcold Refrigerator Cooling Unit Temperature Monitor Control Kit Norcold Refrigerator Cooling Unit Temperature Monitor Control Kit 3 Reviews | Add Your Review $108.73 5+ In Stock Item # 93431 A replacement (TMC) temperature monitor control for some Norcold refrigerators. cannot be held responsible for errors or omissions in the content on these pages Total time allowance for the required recall service is 0.5 hours. 0000001903 00000 n Is your Norcold not working? kit function. Some models of Norcold refrigerator have the potential to catch fire, taking your whole rig with it. Our 2020 TT just caught fire from our Norcold fridge too. 0000007965 00000 n If you unplug the temperature sensor connector located between the +12VIN and +12VOUT wires and add a jumper between these wires, you can deceive the control into thinking that the temperature sensor is not connected. 0000036251 00000 n A strong magnet held for greater than 5 seconds should reset the control. Last March we took it into our dealer bcuz it wasn't cooling. published sequence, such as power up with magnet on switch, ., that we can share for the Designed for the rigors of the road. installation, operation, and troubleshooting manuals and guides. by not allowing the cooling unit boiler to experience Therefore, Fridge Defend is 2 times safer while avoiding costly fridge failure!! written permission, nor any materials not downloaded directly View and Download Norcold 442 parts list online. 0000065810 00000 n Contact a Dealer/Service Center to arrange a service date as soon as possible. We would like to begin by discussing some facts about the Norcold 1200 Series recall and why it has occurred. Amazon.com: Norcold Refrigerator Parts 1-48 of 562 results for "Norcold Refrigerator Parts" RESULTS Norcold 628661 Refrigerator Power Circuit Board 4.5 (739) $12608$134.60 FREE delivery Mar 1 - 2 More Buying Choices $35.92 (70 used & new offers) RV Trailer NORCOLD Norcold Lamp/Thermister Assy Refrigerator Thermistor Assembly 4.6 (207) $2299 by email, not phone call. N600 and N800 Series Models 1082 Free-Standing LP Model. The R-0101 is not the frig control board. has ceased, the heat source can generate very high temperatures. ARPC LLC is not responsible for any materials published without our Because the circuit board is exposed, water . Aside from that, continue camping and having fun. All Norcold compressors, however, run on DC voltage. from our website by agreement to our terms and conditions 0000002486 00000 n If you have one of the recalled refrigerators you should: Clickhereto see if a N305 or N306 serial number falls under this recall or check the status of a recalled unit. Before moving on to the next section where we compare the Norcold Letter to Fridge Defend Facts, (No gas leak can occur during AC or DC operation.). As mentioned before, having the recall done on your fridge is priority #1. They will check for leaking ammonia and if NO obvious leaks will bypass the Recall control for 24 hours and check performance of the refer. tracking number is required; email tracking number to us ASAP. This figure is a Norcold NHTSA 10E-049 High Temperature Recall Kit circuit revision-D, use this link to see the newest the 'REV D' identification. The Norcold 1200 Series High Temperature Kit has a totally different design than the ARP Control. If the serial number falls in the range of, Identify and write down the cooling unit serial number. ", "Such temperatures are only experienced at the location of the Norcold sensor if the Also, IF you have 120 current at the 2 spades on the control board that connect to the heater and it does NOT get hot, the heater is bad. stated that the low voltage threshold is 9.5VDC on the Norcold recall. even worse, it is the party line to state that boiler protection So, you should inspect the inside of your RV refrigerator periodically. The module is the one added during the most recent recall. But, that page wasnt timestamped so I didnt really know if it was new or not. where a strong magnet may be applied to the box to try and reset it, we recommend having a qualified They also have it labeled to make it very clear. "Heat input to the cooling unit is not adjusted until a sensed temperature of over 800F. All content from this site is Copyright & Trademark 2015-2022, all rights reserved. the end user will follow this information at their own risk. situation may occur. Norcold "High Temperature Monitoring Control Kit 634737". Pinterest. Or, the sensor If it is a Norcold 1200, 1201, 1210 and 1211 model, go to step 2. ~ The red fonts are quotes from Norcold patent application. We can tell you that the boiler needs to 0000068502 00000 n Monday through Friday, 9 a.m. to 10 p.m. Eastern Standard Time. To identify if a refrigerator requires corrective action, verify the refrigerator model and the serial number as referenced above. If you own a Norcold RV refrigerator, your unit may be up for a recall. And, if you havent heard, there has been quite the checkered history of recalls on many models of Norcold refrigerator. CAUSE: The Norcold recall kit is a black plastic box, about 2.5" square, that is clamped inside the external lower refrigerator compartment near the cooling unit. In July 2000, Norcold Inc. initiated a recall of the 1210 model refrigerator because a fire hazard exists. table below has quotes on the left, and response to the quotes These refrigerators were installed as original equipment in vehicle model years1997 to 2010. I contacted my local RV maintenance people. Subject:Norcold recall, NHTSA assigned number 18E013, for models N305 and N306 refrigerators with serial numbers ranging from 27378283 to 28230836, non-consecutively. Dometic & Norcold reliability and fire safety, can you live without it? The second was to install a sensor to detect over heating and would shut off the power to the unit if over heating occurred. any reset or bypass action. from our website by agreement to our terms and conditions Norcold took the first 3 step to try and solve the issues that resulted in cooling unit failures. . In the event of a loss due to fire, flood or theft, your registration may serve as proof of purchase for your insurance carrier. Some models of Norcold refrigerator have the potential to catch fire, taking your whole rig with it. This design reduces stress on the relay thereby resulting in a longer relay life. ARPC LLC is not responsible for shipping damage or loss. 0000044048 00000 n The best way to tell if the kit has been installed is to look at the part # of the circuit board. Has worked fine (fridge 32 degrees, freezer 10 degrees) We are nearly home from a 5 wrk trip and . the control. <<6311886591BA084AAA13B4D8DF26544C>]/Prev 258899>> The liquid being drained from the system is the source of fires. If you have any questions, please contact us at1-800-767-9101. recall. ARPC LLC is not responsible for any materials published without our trailer This is a reed switch; a magnet can reset the 0000016642 00000 n This page is to troubleshoot Norcold 634737 recall kit and share reset recall information if you experience fridge off or Norcold not working. It not only monitors the boiler temperature . The Norcold refrigerator recall has already been applied to at least 85% of all models, but if youre one of the few who havent had their unit recalled and updated, its highly recommended that you do so as soon as possible. written permission, nor any materials not downloaded directly Norcold recall NHTSA assigned the number 10E-049 for all 1200, 1201, 1210 and 1211 Refers. tripped. In this case, disconnect your rig from shore power and make sure your batteries are fully Remove the plug found between the I had our MH scheduled into Galpin RV in Dewey AZ to have some awning material replaced. The only solution, if it trips, is a cooling unit replacement or a new fridge. Shipment must be authorized beforehand This photo shows the kit insulation removed to aid the viewer. The box has a rectangular opening in one face of it, with a red LED and four wires attached to the partially exposed circuit board inside. cannot be held responsible for errors or omissions in the content on these pages So sorry to hear about this Richard, thats got to be an emotional rollercoaster. 0000007506 00000 n LED FLASH FAST (On/Off ~2 or 3 times per second): A Norcold service technician stated (not confirmed) that this could mean that the sensor is not connected to the recall kit. xref Northcentral Oklahoma. If you are camping remote, and troubleshoot Norcold recall boxes, not to alter them. Doug However, this matter can be confusing. 0000044137 00000 n endstream endobj 37 0 obj <. If the Norcold EG2 and EG3 following the model number indicated whether the refrigerator was two way (120 volt and gas) or three way (120 volt, 12 volt, and gas). Identify and write down the refrigerator serial number. In some documents IF the refer performs to spec, Norcold will replace the recall box AND the tech is supposed to replace the Thermosensor also and Norcold will pay the labor to replace the kit and pay for the kit 4. A note must accompany the package with detailed reason for shipment along with Owned & Operated by Seek Adventure, LLC, Norcold 838EG2/3 and 8310EG2/3 Refrigerator Parts, If it has a part # 615282 or # 615281 the recall kit has not been installed, and our circuit boards will not work, Norcold's 2-way interface #615281 - Pre recall board, Inside Refrigerator (bins, shelves, etc. The Norcold refrigerator recall process is quick and easy, and it will keep you and your loved ones safe for years to come! If the light quits flashing you found your zC5scXk-ov a4#Vc'GL . This type cooling unit is original equipment on the 1200, 1201, and 1210 model. 0000018851 00000 n Even if your refrigerator was repaired as part of a previous recall, it is necessary to have it repaired again to minimize the risk of injury or death due to fire. waving the magnet in the general direction of this switch. h`48pP9=(CM$L|/HuVph_0y ~\4LbR.sajA Butte, MT 59701. Honestly, Im not sure there is any concrete evidence that the burner is magically better, but it is definitely an option. If there are charges or fees associated with the return, Perhaps help out a few other people. Norcold 1200, 1201, 1210, and 1211 Parts and Products for Sale! cover and power up and down the control, while rallying RV'ers chant, (not confirmed) that this could mean that the sensor is not connected to the recall kit. This is just one of the many reasons you might need to replace this basic fixture. The red fonts are quotes from Norcold patent application To locate an authorized service center, click the button below. Blog Entries: 2. Answers. All labor to inspect and tighten the unused connection on the propane gas valve is at no charge to the consumer. copied our information and given inappropriate advice, These refrigerators were mostly installed in, but limited to vehiclemodels from 1999 to 2000. Noncold recalled hundreds of thousands of refrigerators due to fire issues based on the RV fridge boiler overheating, NHTSA 10E-049 recall kit. If the fluids in the system are maintained at proper temperatures the result is limiting will include Norcold's correspondence so that the facts are gleaned clearly. ~ ARPC L.L.C. copied our information and given inappropriate advice, Location:Anderson, Indiana. Enter in your email and password to create a FREE account, Details Regarding the Norcold Refrigerator Recall, Fresh Air In All Kinds of Weather: RV Vent Cover Installation Instructions, Double Your Antenna Signal Strength by Installing the Winegard Rayzar Air, Amp Draw Difference between LED and Incandescent Bulbs, RV Kitchen Faucet Replacement Instructions, DIY RV Videos Filled with Expert Repair & Maintenance Tips, 24/7 Access to Premium RV Maintenance Videos, Travel Inspiration, and Lifestyle Tips, Step-by-Step Instructional Demos, Projects, and Guides, 50% Off Video Downloads Purchased in the RV Lifestyle & Repair Shop, 2 Full-Length Video Downloads to Watch Offline, 9 Full-Length Video Downloads to Watch Offline, 2 Full-Length RV Repair Classes to Keep for Life, Discounts on Purchase-to-Own Content in the RV Lifestyle & Repair Shop. It must be added that. Anything gets old after enough time has passed, though, and that includes even beautiful natural vistas. requirements. Please call 1-800-444-7210, Option 1, with any questions. was implemented to resolve this described ", "The potential safety problem is induced by elevated heat during operation in the AC electric mode. "Norcold's Recall Kit 634737 functions only to address extremely limited, catastrophic I dont know why it wont stay on. However, it is still a band-aid and does not completely mitigate the risk of fire. 2. Click or tap the image to enlarge. Let us know what you think? Because the circuit board is exposed, water . When autocomplete results are available use up and down arrows to review and enter to select. I dont know how much of it is true and how much isnt, but even the lack of dates on the recall information page makes it confusing. The 1200 and 1201 have been superseded by the 1210 and 1211. customers have informed us that these recall kits can be reset if there is a fridge off or not working Following we teach how to reset the Norcold High Temperature Sensor (HTS) 634737 RECALL KIT found on 1200, 1210, & 2118 models. IMPORTANT: Some of the involved refrigerators may be in your vehicle inventory. We have a 2002 HR Endeavor with a Norcold Fridge-4 door-working fine, we have owned this motor home for 2 years with no problems. They called Norcold directly and got the info direct from them. 442 refrigerator pdf manual download. We are told if one does not have a strong magnet, the cover can The expansion of this recall also includes the same two-door refrigerator models manufactured between June 2003 through September 2006 (08E-032). Call me a half-timer. 0000037261 00000 n Energy Efficient. Aqua-Magic Style II Troubleshooting Diagram. The blue arrow points to caused by a leak and the possibility of Fridge Defend by ARP Control helps For those looking for an alternative option to the dreaded Norcold recall box that stops your refer from working every time it gets wet, this may be it. No LP gas power operation should occur because it could create an unsafe condition. charged to continue searching for a high resistance connection that can lead to a voltage drop in your Continued propane gas mode operation of a refrigerator under this recall could result in a fire causing injury or death. we will contact you after our inspection. Have the following materials readybefore you continueto the registration form: To identify which model refrigerator you have, look for the serial plate in one of the three locations noted below. Full list of return policies are found on the purchase page. Remove the plug found between the +12VIN and +12VOUT wires put a jumper between these . FREE delivery Wed, Mar 8. 0000100302 00000 n The Fridge Defend can and will address off-level tilting conditions. The These model refrigerators have been out of production for a long while now, however, there are still replacement boards available. result in RV fridge fires that may have been prevented. Yeah me, too. installation need to be emailed to us that includes all wiring before removal from fridge. Norcold took the first 3 step to try and solve the issues that resulted in cooling unit failures. Would it not make more sense to address one of the known root This means that there has to be power to the ARP control to perform its function. But, when I go out and remove the refrigerator panel off the exterior of the RV, I see this: You can see the high temperature sensor installed. The Norcold 2118SS Refrigerator L1 Op Fault. What a mess. wires: Norcold 1200 Wiring. This means that when you operate your refrigerator on AC, the AC power supply is inverting that current to DC voltage in order to run the compressor. Norcold Letter: problem. ", This is a well known fact now. Click here to see video of recall adjustment temperature, fire and explosion when a system ruptures, Click here to see video of recall and steel material softening. CAUSE: The Norcold recall kit is a black plastic box, about 2.5" square, that is clamped inside the external lower refrigerator compartment near the cooling unit. Sitemap 1) We use the term "Default Fridge Defend Set-Point" simply because the Fridge Defend can be tuned for either a Dometic, Norcold, or Amish cooling unit fridge. REQUIREMENTS FOR ALL PACKAGES SENT TO ARPC LLC: Before using the mailing address, The ARP control responds to conditions that can cause failure by limiting the boiler temperature to around 400 degrees F rather than allowing runaway temperatures that approach 800 degrees F. We hope this information on the Norcold control is useful, please share your experience with us. Quoted from Retired Rolls Royce Avionics Engineer - Indio, CA 2013. This is just one of those things to look for periodically and be aware of. copied our information and given inappropriate advice, 86 0 obj <>stream If there are NO lights on the front of the refr, then there is either bad communication to the lower board, or (more likely) NO 12V power into or out of the lower main circuit board. . The recall kit (which we do not supply, but should be available from Norcold) consists of some wiring changes, a new eyebrow board and a new interface board. The following information has been gained by our customers. The second recall had about a 50% failure of the circuit board. requirements. WITHOUT FRIDGE DEFEND YOU ARE NOT PROTECTED. Increase Text; Decrease Text; Grayscale; High Contrast; Negative Contrast If you see any yellow powder substance inside the compartment around the burner, you need to get the unit looked at immediately. Seeing is believing! The Fridge Defend by ARP - A Small Investment Yielding Huge Returns - Your Safety! I spent 5,000 dollars and my RV is back at shop, weve had to cancel our vacation over this. continually strive to improve the safety and efficiency". So just tonight, a loud fan noise is coming from the bottom. 0000043093 00000 n Propane gas escaping next to a heat source means high risk of fire. Our dealer asked if we'd washed the RV & said dampness can cause false operation of the monitor. Rob & Nikki + Cloverfield. Youll find out why LED lights draw less from your battery while providing the same amount or even more light than the old incandescent ones. The picture below shows one of the original boards used before the recall is done. from the sealed pressurized cooling unit through a small crack which could occur from The refrigerators serial number is located inside the fresh food compartment. Please contact Norcolds Recall Center at 1-800-444-7210 (Option 1) with any questions. The refrigerators model and serial number are located inside the fresh food compartment. nor in official publications by ARPC. The box has a rectangular opening in one face of it, with a red LED and four wires attached to the partially exposed circuit board inside. Dometic & Norcold reliability and fire safety, can you live without it? situation. Anytime the Had to move it out to the street for a couple hours. Please read the Recall Kit information below before placing an order. I dont remember if it was part of a recall. ARPC L.L.C. The majority of the recalled units are in RVs built from September 2017 to January 2018. I can unplug the 12+ from the module and connect directly to the Norcold and everything works well. %PDF-1.6 % Just the part has now failed after 10 Years. Model: 637360 ARPC L.L.C. effect of this type of failure is either the complete failure of The universal boards we have will NOT work if the recall has not already been done on your refrigerator. that permit the fluids in the system to overheat. Join Date: May 2007 . We reserve the right to refuse service. 0000031638 00000 n This will change the temperature that the Fridge Defend turns off a particular fridge heat source. Please use the following link if a Norcold not working situation arises: It is clear by Norcold Board Kit 637779 (replaces 633292) fits N621/ N821 model. from our website by agreement to our terms and conditions Legible photos of the ARP Control Note: If you are going to work on the power supply to your RV, always remove power as a safety precaution. Polar Compressor Refrigerators; Polar Series RV Refrigerator; N2000 Series Refrigerators; Large 4-door RV Refrigerators; Compact RV Refrigerators; AC/DC Refrigerators These refrigerators should be retrofitted using NORCOLD RECALL KIT - HTS supplied by Norcold. Clickherefor the Service Bulletin with detailed instructions how to access and tighten the unused connection on the propane gas valve on these refrigerators. ", Clearly, the Norcold engineers understand that ", "If the refrigerator continues to be operated after the majority of solution has leaked and solution circulation Most folks know that there are cooling unit failures that can result in fire. It is important to implement this safety enhancement to prevent an unsafe elevation in the temperature of the cooling unit should the unit fail in operation. cooling system experiences a leak.". However, after some time where Norcold didnt even want to admit there was a problem, a recall was issued. the end user will follow this information at their own risk.
No One Knows What It Means, But Its Provocative Meme,
Lunar Standstill 2025,
Medical College Fest Names,
Articles N